TM 5-2320-262-20-3
Notify Direct Support maintenance.
SPRUNG/UNSPRUNG CONTROL VALVE LINKAGE CHECK
Hold measuring device (1) on face of SPRUNG/UNSPRUNG control valve (2). Have
assistant move SPRUNG/UNSPRUNG lever between SPRUNG and UNSPRUNG
mode. Measure distance plunger (3) travels as lever is moved. Distance of travel
should be 9/32 in. (7 mm).
Refer to TM 5-2320-262-20-2.
3-117