TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 1. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CS Scraper - Continued.
LOCATION
ITEM TO
ITEM
MAN-
NOT FULLY MISSION
CHECK/
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
SERVICE
28
Annual
Fuel Tank
Drain
WARNING
DO NOT perform fuel system checks, inspections or mainte-
nance while smoking or near fire, flames or sparks. Fuel may
ignite, causing damage to machine and injury or death to per-
sonnel.
Operating personnel must wear fuel-resistant gloves when han-
dling fuels. If exposed to fuel, promptly wash exposed skin
and change fuel-soaked clothing. Failure to do so may result in
injury to personnel. Failure to do so may result in injury to per-
sonnel.
Access fuel tank drain valve by open-
ing rear compartment access door at
rear of scraper. Attach a suitable drain
hose, open drain valve, and drain any
water/sediment from fuel tank into a
suitable container. Close drain valve
and remove drain hose.
FUEL TANK
DRAIN VALVE
390-012
0010 00-31