TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
a. Remove front guard parts under
30
Biennial
Crankshaft
tractor to access front of engine
Vibration
Damper
NOTE
Vibration damper has a weight located inside a silicone
fluid-filled case.
b. Inspect damper for dents, cracks or
evidence of leaks. If a fluid leak is
found, determine type of fluid. Sili-
cone fluid is transparent, viscous,
smooth, and difficult to remove
from surfaces. If leak is oil, crank-
shaft seals are suspect. Notify DS
Maintenance if damper is dented,
cracked or fluid leaks are evident.
VIBRATION DAMPER
0010 00-71