AIR TANKS REPLACEMENT - CONTINUED
0094 00
REMOVAL - CONTINUED
8.
Loosen nut (18) and disconnect hose (19).
16
15
14
9.
Loosen nut (14) and disconnect hose (15).
10.
Loosen nut (17) and disconnect hose (16).
18
19
17
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable lift capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
NOTE
Three air tanks together weigh 132 lb (60 kg).
11.
Place lifting device under air tanks (20) and remove
20
21,22,23
four bolts (21), eight washers (22), and four nuts (23).
12.
Carefully lower air tanks (20).