TM 5-3805-248-23-1
BATTERY, STARTING AND CHARGING SYSTEM TROUBLESHOOTING
PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Starting Motor
6.
Inoperative - Continued.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
b. Set multimeter to appropriate
ground.
394-1620
d. Place battery disconnect switch in
1. If voltage is indicated, repair open
ON position (TM 5-3805-248-10).
circuit between ammeter and start
switch.
2. If voltage is not indicated, replace
0010 00-10