TM 5-3805-248-23-1
TRANSMISSION OIL DRAIN AND REFILL - CONTINUED
0128 00
DRAINING
NOTE
Use a container to capture draining oil. Dispose of oil IAW local policy and ordinances. Ensure all spills are
cleaned up.
1.
Remove plug (1) and drain oil (approximately 22 gallons ([83.3 l]).
2.
Remove and discard preformed packing (2) from plug (1).
2
1
394-258
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear eye protection.
1.
Remove preformed packing material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect plug for damage and replace as necessary.
5.
Inspect used oil for foreign material and contact supervisor if foreign material is found.
0128 00-2