TM 5-3805-248-23-1
HEIGHT CONTROL VALVE REPLACEMENT - CONTINUED
0215 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Remove all preformed packing material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Install two valve actuator assemblies (19) on height control valve (10).
2.
Install valve actuator (23) and height control valve (10) on seat.
3.
Install two sleeves (18) and nuts (17) on height control valve (10).
4.
Install slide (22), washer (21) and screw (20) on valve actuator rod (23).
5.
If removed, install new preformed packing (9), adapter (8) and elbow (7) on bottom of height control valve (10).
0215 00-3