TM 5-3805-248-23-2
HYDRAULIC IMPLEMENT PUMP REPLACEMENT - CONTINUED
0322 00
REMOVAL - CONTINUED
WARNING
Use caution when handling heavy parts. Provide adequate support and use assistance during procedure.
Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of heavy
parts supported only by lifting device. Failure to follow this warning may cause injury or death.
NOTE
Weight of hydraulic pump is 120 lb (54 kg).
8.
Install lifting device on hydraulic pump.
9.
Remove two nuts (14) and washers (15).
10.
Use lifting device to remove hydraulic pump. Pull out toward front of machine to disengage pump shaft from drive gear.
11.
Remove and discard preformed packing (16).
NOTE
HYDRAULIC PUMP
Remove two studs only if inspection indi-
cates replacement is necessary.
12.
Remove two studs (17), if necessary, from transfer
case.
13.
Remove lifting device.
394-1058
17 16
14
15
0322 00-3