TM 5-3805-248-23-2
STARTING MOTOR (DELCO-REMY) REPAIR - CONTINUED
0361 00
DISASSEMBLY - CONTINUED
44. Remove nut (74), washer (73) and two washers (72).
45.
Remove eight screws (75).
46.
Remove bushing (71) by bending up three tabs on commutator end of field coil (19). Pull wire assembly of field coil
(19) through inside of housing (13). Remove four shoes (76) and field coil (19).
NOTE
Remove field coil only if testing and inspection proves replacement is necessary.
Four shoes have a long lip on one side and a short lip on the other. The long lip should be assembled in
the direction of armature rotation so it becomes the trailing (not leading) edge of the pole shoe.
47.
Remove field coil (19), if necessary, insulator (70) and four shoes (76).
74
73
72
70
71
75
13
19
76
394-1380
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Remove all seal and preformed packing material from all mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
0361 00-7