TM 5-2350-262-20-3
ACCUMULATOR DUMP VALVE INSTALLATION - CONTINUED
H
Disconnect ACCUMULATOR-9 hose (11)
from elbow (12) at bottom of main hydraulic
accumulator (13).
I
Install tee (14) on elbow (12), and connect
hose (11) and hose assembly (10) to tee (14).
LEGEND
8
Adapter
1
Plug
9
Globe Valve
2
Packing
10
Hose Assembly
3
Port 7
11
Accumulator Hose
4
Valve 13R
12
Accumulator Elbow
5
Nipple
6
Reducer
13
Accumulator
7
Tube Assembly
14
Tee