TM 5-2350-262-20-3
EJECTOR CONTROL VALVE LINKAGE CHECK
Stop engine; relieve hydraulic pressure.
Hold a measuring device (1) on the face of ejector control valve (2). Have assistant move
EJECTOR CONTROL lever between FORWARD and BACK. Measure distance plunger
(3) travels as lever is moved. The distance of travel should be 9/32 in. (7 mm).
3-55