TM 5-2350-262-20-3
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE
7
(CONTINUED)
NO
from block 2
8
Perform main relief valve pressure test.
Is hydraulic pressure between 3,950-4,050 psi (27,235-
27,925 kPa)?
NO
YES
To block 27
To block 9
3-94