HYDRAULIC OIL OVERHEATS (CONTINUED)
YES
YES
NO
from block 17
from block 18
from block 18
19
Stop engine; relieve hydraulic pressure.
Remove all test equipment and connect lines.
Replace directional control valve bank.
20
Stop engine; relieve hydraulic pressure.
Remove all test equipment and connect lines.
Verify problem is solved.
21
Perform suspension raise/lower relief valve test.
Is pressure 3,450-3,550 psi (23,788-24,477 kPa)?
YES
NO
Stop engine; relieve hydraulic
pressure. Remove all test
equipment and connect lines.
22
Perform suspension raise/lower relief valve adjustment.
Can pressure at suspension raise/lower relief valves be
adjusted to 3,450-3,550 psi (23,788-24,477 kPa)?
To block 25
NO
YES
To block 24
To block 23