TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 1. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CS Scraper - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
b. Release retainer and remove cover.
0.6 Hours Brake Fluid
4
250 Hours
Clean diaphragm with a clean rag.
Reservoirs,
(Con't) or Semi-
Remove diaphragm.
Master Cyl-
annual
inders,
c. Brake fluid level should be 1/2 in.
Brake Lines,
(13 mm) down from top of reser-
and Fittings
voir. Add brake fluid (Item 4, WP
d. Ensure diaphragm and cover are
clean. Install diaphragm and cover.
Secure cover with retainer.
BRAKE FLUID
RETAINER
COVER
RESERVOIR
DIAPHRAGM
390-012
0010 00-4