TM 5-3805-248-23-1
DUST EJECTOR AND INLET PIPING AND MOUNTING MAINTENANCE - CONTINUED
0032 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear eye protection.
INSTALLATION
1.
Remove all gasket material from mounting surfaces.
2.
Clean all metal parts with solvent.
3.
Clean all rubber or plastic parts with detergent.
4.
Dry all parts with compressed air.
5.
Inspect all parts for damage and replace as necessary.
1.
Loosely install clamps (17) on hose (18) and install hose on turbocharger.
2.
Install support (11) three new lockwashers (12), washers (13) and bolts (14).
3.
Install new gasket (20), pipe (19), four new lockwashers (15) and bolts (16).
4.
If removed, install eight new studs (10) in support (11) and torque to 20 lb-ft (27 Nm).
0032 00-4