TM 5-3805-248-23-1
HYDRAULIC TANK HOSES, LINES AND FITTINGS REPLACEMENT - CONTINUED
0233 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove all preformed packing and seal material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Install new ring seal (92) and tube assembly (86) on hydraulic tank.
2.
Install four washers (91) and bolts (90) on tube assembly (86).
3.
Install new preformed packing (87) and tube assembly (85) on tube assembly (86).
4.
Install two washers (89) and bolts (88) on tube assembly (86).
5.
Install angle bracket (81), two washers (83) and capscrews (82) on top of transmission.
6.
Install retaining straps (76 and 84), two washers (78), capscrews (77), washers (80) and nuts (79) on tube assembly (85).
77,78
79,80
76
81
82,83
394-539
85
84
0233 00-9