TM 5-3805-248-23-2
PRESSURE AND SELECTOR VALVE ASSEMBLY REPLACEMENT - CONTINUED
0364 00
REMOVAL - CONTINUED
56.
Remove two retaining rings (100) and dowels (99) from selector valve assembly (101).
101
100
99
394-699
57.
Remove plate (103), retaining clip (102) and sleeves (104 and 106).
58.
Remove and discard two preformed packings (105 and 107).
103
102
104
107
105
106
0364 00-13