TM 5-3805-248-23-2
HYDRAULIC IMPLEMENT PUMP REPAIR - CONTINUED
0380 00
ASSEMBLY - CONTINUED
5.
Turn housing (12) over and install new preformed
packing (25).
NOTE
18
Lip of new seal should be toward inside of
housing, even with bottom of counterbore.
6.
Use driver and hammer to install new seal (18).
25
12
394-1408
7.
Install coupling (29) on shaft (19).
8.
Using snap ring pliers, install ring (30).
WARNING
Hot oil or metal parts can cause severe burns. Wear insulated gloves, long sleeves and eye protection when
working with heated parts. Failure to follow this warning may cause injury.
9.
Use clean oil to heat bearing (27) to a maximum tem-
perature of 275F (135C).
10.
Install bearing (27).
26
11.
Use snap ring pliers to install ring (28).
30
27
12.
Install ring (26) on shaft (19) from coupling (29) end
29
of shaft.
28
19
394-1402
0380 00-8