TM 5-3805-248-23-2
SEQUENCE VALVE REPAIR - CONTINUED
0382 00
ASSEMBLY - CONTINUED
2.
Install new preformed packing (8) and plug (7).
1
2
3.
Install piston assembly (6) in sequence valve (3).
4.
Install new preformed packing (4) and plug (5).
3
5.
Install new preformed packing (2) and plug (1).
4
9
5
6
8
7
394-1430
6.
TESTING
NOTE
Prior to testing, battery negative ground
must be connected.
SCRAPER CONTROL
1.
Remove plug (5) from side of sequence valve (3).
VALVE
2.
Install adapter in place of plug (5).
ADAPTER
3.
Install hose assembly and pressure gage on adapter.
HOSE ASSEMBLY
5
3
394-1432
0382 00-4