TM 5-2350-262-20-3
1
ALL HYDRAULIC FUNCTIONS INOPERATIVE (CONTINUED)
YES
from block 7
9
Check hydraulic pressure at port 13R.
Is pressure 3,950-4,050 psi (27,235-27,925 kPa)?
NO
YES
10
Perform 13R main relief valve adjustment.
Can hydraulic pressure be adjusted
3,950-4050 psi (27,235-27,925kPa?
YES
NO
11
Remove all test equipment and connect hoses.
To block 12
Replace directional control valve bank.
3-24