TM 5-2320-262-20-3
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE
8
(CONTINUED)
NO
from blocks 1
and 2
15
Perform forward manifold pressure test.
Is pressure greater than 2,500 psi (17,238 kPa)?
NO
YES
To block 19
16
Check for blockage between inlet port 9 of
forward manifold and port 9 of No. 1 actuator.
Is there blockage?
YES
NO
17
Clear blockage.
Verify problem is solved.
18
Verify problem with operator.
3-120