TM 5-3800-205-10-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0012 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
AIR SYSTEM AND BRAKES - CONTINUED
5. Service Brakes Do Not Operate Correctly
3. Check for air/hydraulic oil
3. If problem still exists, notify
- Continued.
leaks or damage to brake
Unit Maintenance.
system components.
WARNING
Park machine on level ground, stop engine, and lower bowl to prevent injury to operator and/or
severe damage to machine.
6.
Service Brakes
Do
Not
Release
1. Check for mud or dirt under
1. Clean mud or dirt from under
Correctly.
brake pedal
brake pedal. If problem still
exists, go to test step 2.
2. Check air/hydraulic hoses for
2. Connect air/hydraulic hoses if
loose connections.
required. If problem still
exists, go to test step 3.
3. Check for air/hydraulic oil
3. If problem still exists, notify
leaks or damage to brake
Unit Maintenance.
system components.
CHARGING SYSTEM
1.
NOTE
A thirty (30) minute cool down time may be required before circuit breaker can be reset.
1. Check that circuit breaker at
1. Reset circuit breaker. If
fuse/circuit breaker panel in
problem still exists, go to test
cab is not tripped.
step 2.
2. Check for loose or broken
2. If loose or broken drive belt is
drive belt.
found, or if drive belt is okay
and problem still exists, notify
Unit Maintenance.