TM 5-3800-205-10-1
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CS Scraper - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
WARNING
If machine is parked indoors, DO NOT run engine
unless exhaust fumes are vented to the outside.
Failure to follow this warning may cause injury or
death due to carbon monoxide.
a. Start engine and repeat EMS self- a. Engine will not start.
30
Before
Engine Star-
Warning lights and alarm
tup
stay on.
indicators, warning lights, and
alarm operate properly on EMS dis-
play. If EMS indicates no engine oil
pressure, shut down engine and
notify Unit Maintenance.
b. Check operation of lights (service b. Any lights do not func-
and blackout lights, brake lights,
tion, if required for mis-
turn signals, work lights, etc.).
sion.
c. Adjust rearview mirror as required:
Loosen two knobs on either side of
mirror, adjust mirror, and tighten
knobs.
Any hydraulic system or
31
Before
Hydraulic
Perform a functional check of all
function does not operate
Controls
hydraulic systems: steering, bowl lift,
properly.
ejector, floor, and elevator circuits.
Ensure elevator operates properly in
reverse and in low and high forward
speeds.
32
Before
Backup
a. Verify that backup alarm functions a. Backup alarm does not
Alarm and
when transmission is placed in R
function, if required for
Horn
(Reverse).
mission.
b. Check operation of air-operated b. Horn does not operate, if
horn on steering wheel.
required for mission.
0014 00-24