TM 5-3800-205-10-1
AIR TRANSPORT BY C-130 AIRCRAFT - CONTINUED
0018 00
CONFIGURE MACHINE FOR AIR TRANSPORT - CONTINUED
CAUTION
Always wipe ends clean prior to disconnecting hydraulic lines. Ensure ends are clean prior to reconnecting.
Failure to do so may introduce contamination into hydraulic system.
NOTE
To facilitate disconnection of hydraulic hose quick disconnect fittings, relieve any trapped hydraulic
pressure in hoses by operating control levers through all positions (WP 0004 00).
Review all load transfer valve and hose assembly installation steps before proceeding, to aid in under-
standing installation steps.
14.
Install load transfer relief valve and hose assembly to bowl lift cylinder plumbing and to elevator motor drain line at left
side of machine:
a.
Disconnect hose A quick disconnect from tube C. Disconnect hose B quick disconnect from tube D.
HOSE A
TUBE C
TUBE D
HOSE B
0018 00-23