TM 5-3800-205-23-1
CIRCUIT BREAKERS REPLACEMENT - CONTINUED
0038 00
15-AMP CIRCUIT BREAKER REMOVAL
NOTE
There are two 15-amp circuit breakers used.
1.
Perform steps 1 through 6 of 60-Amp Circuit Breaker Removal.
2.
Remove two screws (41), washers (42), and circuit breaker (43) from fuse/circuit breaker panel (15).
41,42,43
15
NOTE
Tag leads to aid in installation.
3.
Remove two screws (44), starwashers (45), and leads (46) from terminals (47). Discard starwashers.
44,45
46,47
44,45
46,47
0038 00-7