TM 5-3800-205-23-1
CIRCUIT BREAKERS REPLACEMENT - CONTINUED
0038 00
60-AMP CIRCUIT BREAKER INSTALLATION
1.
Install lead (25), new lockwasher (24), washer (23), and nut (22) on right terminal (26). Tighten nut to 9 lb-in. (1 Nm).
2.
Install new lockwasher (20), two leads (19), washer (18), and nut (17) on left terminal (21). Tighten nut to 9 lb-in. (1
Nm).
3.
Install plate (13) and circuit breaker (14) on fuse/circuit breaker panel (15) with two screws (16).
4.
Position cable and clamp (12) on left side of fuse/circuit breaker panel (15).
5.
Install panel (15) with three bolts (10) and washers (11).
6.
Install top access panel (3) and with five screws (1).
7.
Install top three bolts (4) and two brackets (5) on switch panel (2).
8.
Slide cable (8) into grommet (9) on right panel (6).
9.
Install right panel (6) with nine screws (7).
6
3
2
4,5
7
1
8,9
390-1221
0038 00-3