TM 5-3800-205-23-1
BATTERY DISCONNECT SWITCH REPLACEMENT- CONTINUED
0037 00
INSTALLATION
1.
Install new lockwasher (14) on switch (2).
NOTE
Align switch guide pin with hole in mounting bracket when installing switch.
2.
Position switch (2) on mounting bracket (16).
3.
Install plate (15) on mounting bracket (16) with new lockwasher (14) and nut (13).
4.
Install electrical lead (11) and cable lead (10) on right terminal (12) with new lockwasher (9) and nut (8).
5.
Install cable lead (7) on left terminal (4) with new lockwasher (6) and nut (5).
6.
Install rubber boots (3) over terminals (4 and 12).
7.
Install key (1) in switch (2).
8.
END OF WORK PACKAGE
0037 00-3