TM 5-3800-205-23-1
AIR COMPRESSOR GOVERNOR AND AIR COMPRESSOR MAINTENANCE - CONTINUED
0083 00
AIR COMPRESSOR INSTALLATION - CONTINUED
13.
Connect two hoses to air compressor governor (Refer to steps 4 through 6 of Air Compressor Governor Installation).
14.
15.
Place battery disconnect switch in ON position (TM 5-3800-205-10-1 or TM 5-3800-205-10-2).
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside. Failure to
follow this warning may cause injury or death due to carbon monoxide poisoning.
16.
Start engine and fully charge air system (TM 5-3800-205-10-1 or TM 5-3800-205-10-2). With assistance, check for
leaks.
17.
AIR STRAINER REMOVAL
1.
Remove two bolts (44) and washers (45) from elbow (43).
2.
Remove elbow (43), gasket (41), strainer element (42), gasket (41), and check valve (40) from air compressor (21). Dis-
card gaskets.
21
40
41
42
43
41
44
45
390-2056
0083 00-8