TM 5-3800-205-23-1
ELEVATOR/WATER HYDRAULIC PUMP REPLACEMENT - CONTINUED
0159 00
REMOVAL - CONTINUED
8.
With assistance, remove two bolts (17), elevator pump
(5), and O-ring (16) from torque converter. Discard O-
16 (HIDDEN)
ring.
17
5
INSTALLATION
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in injury or death to
personnel.
NOTE
Elevator pump weighs 77 lb (35 kg).
Lubricate all new O-rings with clean oil before installation.
1.
With assistance, install new O-ring (16) and elevator pump (5) on torque converter with two bolts (17).
0159 00-4