CHAPTER 2 OPERATING INSTRUCTIONS
Gages and Indicators

Scraper, Earth Moving, Motorized, Diesel Engine Driven Model 621B
Page Navigation
  14    15    16    17    18  19  20    21    22    23    24  
img
. .
TM 5-3805-248-10
DESCRIPTION AND USE OF OPERATOR CONTROLS AND INDICATORS
0004 00
GENERAL
Do not attempt to operate the scraper until becoming familiar with the location and use of all controls and indicators. This
work package describes all operator controls and indicators.
INSTRUMENT PANEL
1.
Gages and Indicators.
2
3
4
1
394-155
KEY
CONTROL OR INDICATOR
FUNCTION
1
Low Air System Pressure
Illuminates when the air system pressure is below 65 psi (448 kPa).
Indicator
Alarm buzzer will also sound.
2
Engine Coolant Temperature
Indicates temperature of engine coolant. Normal operating range is in
the white range or green range. Red range indicates overheating
condition.
3
Air Pressure Gage
Indicates air system pressure. Normal operating pressure is 110 +/-10
psi (758 +/-69 kPa). When air system pressure drops below 65 psi (448
kPa), warning buzzer will sound and the warning indicator will
illuminate.
4
Service Hour Meter
Records total engine operating hours. Used to determine service
intervals.