TM 5-3805-248-23-1
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0018 00
MULTIMETER USAGE - CONTINUED
(c) Multimeter "C" is used to measure voltage drop across a load, in this case a lamp. If voltages at multi-
meters "A" and "B" are 0.1 volt each, voltage reading at multimeter "C" will equal 23.8 volts. This is
because the sum of all voltage drops in a circuit is equal to the source voltage.
24-VOLT
BATTERY PACK
GOOD SPLICE
CONNECTION
SWITCH
LAMP
(CLOSED)
394-1746
C
0018 00-16