CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear eye protection.
1.
Remove all seal material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
If removed, install two new seals (5) on lower front access plate (6).
2.
Position plate (6) on front left side of operator compartment.
3.
Install eight washers (4) and bolts (3) on lower front access plate (6).
4.
Position clamp and install washer (8) and bolt (7) securing air hoses and harness assembly to weldment.
5.
Position air dryer assembly and install four washers (2) and bolts (1) on lower front access plate (6).
6.
Install operator's compartment upper front access plates (WP 0192 00).
3,4
AIR DRYER
1,2
ASSEMBLY
5
(HIDDEN)
6
394-353
CLAMP
7,8
END OF WORK PACKAGE