TM 5-3805-248-23-2
FAN AND FAN DRIVE MAINTENANCE - CONTINUED
0282 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear eye protection.
1.
Remove all preformed packing and seal material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
ASSEMBLY
1.
Fill fan clutch hub (17) with grease.
2.
Install bearing (18), spacer (19) and bearing (20) in fan clutch hub (17).
3.
Use driver and hammer to install new seal (16) with lip toward outside. Lubricate lip of new seal (16) lightly with
grease.
4.
Install fan clutch assembly in pulley (12).
5.
Install spacer (15) and bracket (14).
6.
Apply sealant to threads of two capscrews (10).
7.
Install washer (11) and two capscrews (10).
8.
Install six bolts (13).
0282 00-5