TM 5-3805-248-23-2
PREPARATION FOR STORAGE AND SHIPMENT
THIS WORK PACKAGE COVERS
Preparation for Return to Service from Long-Term
Preparation for Short-Term Storage
Storage
Preparation for Return to Service from Short-Term
Preparation for Shipment
Storage
Preparation for Long-Term Storage
NOTE
Short-term storage is storage for two weeks or less. Long-term storage is for more than two weeks.
PREPARATION FOR SHORT-TERM STORAGE
1.
Thoroughly clean machine.
2.
Perform Operator Preventive Maintenance Checks and Services (PMCS) (TM 5-3805-248-10).
3.
Fill fuel tank completely to prevent condensation from forming (TM 5-3805-248-10).
4.
Perform Unit PMCS (WP 0019 00 and WP 0020 00).
5.
Schedule next PMCS on ULLS-G (Unit Level Logistics System Ground).
6.
Store machine indoors in a dry, protected area with scraper bowl lowered to the ground (TM 5-3805-248-10).
7.
When moderate temperatures are expected, leave batteries in place. If extreme cold is expected, remove batteries (WP
0103 00) and store in a protected area.
8.
Check engine coolant to ensure coolant has correct mixture for expected temperatures (TB 750-651).
9.
Seal all openings in engine, including air intake, exhaust outlet, and crankcase breather tube.
10.
Ensure battery disconnect switch is in OFF position (TM 5-3805-248-10).
11.
Fill in Form DD 1397 completely and attach to a conspicuous part of machine.
PREPARATION FOR RETURN TO SERVICE FROM SHORT-TERM STORAGE
1.
Remove seals from all engine openings, including air intake, exhaust outlet and crankcase breather tube.
2.
If removed, install batteries (WP 0103 00).
3.
Check oil and hydraulic fluid levels in engine crankcase, transmission, front axle differential, wheel end final drives and
hydraulic reservoir.
4.
Check coolant level in radiator (TM 5-3805-248-10).
5.
Start engine and perform machine warmup (TM 5-3805-248-10). Verify proper operation of all gages, switches and
lights.
6.
Ensure fuel tank is full (TM 5-3805-248-10).
7.
Operate machine without a load and check engine, transmission, brakes, steering and electrical accessories for proper
operation (TM 5-3805-248-10).