26.
Check test result of recorded ammeter reading. If read-
ing is 4 to 5 amperes, proceed to step 27. If reading is
0 amperes, solenoid winding is open (broken wire).
Replace solenoid. If reading is 6 volts or higher, sole-
SOLENOID
noid winding is shorted. Replace solenoid.
KNIFE SWITCH
CARBON PILE
BATTERY
394-1394
DISASSEMBLY
NOTE
Before disassembly, solenoid must be disconnected from test setup.
1.
Remove four nuts (6).
2.
Separate cover (1) assembly from housing (2) to access screw (4).
3.
Remove screw (4).
NOTE
Tag all wire connectors, cables and wiring harnesses prior to disconnecting to ensure correct installation.
4.
Disconnect wire connector (3) from terminal (5).
5.
Remove cover (1) assembly from housing (2).
2
1
3
5
4
6
394-1395
0363 00-5