80.
Remove dowel (154) and pin (156).
153
81.
Use a hammer and brass driver to remove two bear-
154
156
ings (153) from detent (155).
155
153
394-689
WARNING
Dry cleaning solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic material.
However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove all seal and preformed packing material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry parts with compressed air.
4.
Visually inspect parts for damage. Replace damaged parts as necessary.