TM 5 3805-260-24
(1) Torque for bolts that hold impeller
to turning housing ...............20 1 lb. ft. (27 1 N·m)
(2) Clearance between turbine and turning housing:
Across the diameter............ .020 to .040 in. (0.51 to
1.02 mm)
Maximum permissible clearance:
Across the diameter..................................... .045 in.
(1.14 mm)
Running.................................... .0225 in. (0.57 mm)
(3) Torque for bolts that hold retainer
to turning housing ...............36 2 lb. ft. (49 3 N·m)
(4) Torque for bolts that hold drive gear
for pump to impeller ...................20 1 lb.. ft.. (27 1
Nm)
(5) Torque for bolt that holds bearing on
output shaft .....................81 4 lb.. ft.. (110 5 N·m)
(6) Torque for the bolts that hold stator
to the converter housing .......362 lb.. ft.. (49 3 N·m)
(7) Torque for the bolts that hold stator
to the carrier......................20 1 lb.. ft.. (27 1 N·m)
(8) Torque for the bolts that hold flange
to the output shaft
36 2 lb. ft. (49 3 Nm)
(9) Gap in seal rings. .005 to .015 in. (0.13 to 0.38 mm)
(10) Clearance between stator and turbine:
Across the diameter.. .012 to .018 in. (0.30 to 0.46
mm)
Running............... .006 to .009 in. (0.15 to 0.3 mm)
Maximum permissible clearance:
Across the diameter.................. .030 in. (0.76 mm)
Running..................................... .015 in. (0.38 mm)
(11) Clearance between stator and impeller:
Across the diameter. . .009 to .015 in. (0.23 to 0.38
mm)
Running......... .0045 to .0075 in. (0.11 to 0.19 mm)
Maximum permissible clearance:
Across the diameter.................. .024 in. (0.61 mm)
Running..................................... .012 in. (0.30 mm)
(12) Torque for bolts that hold retainer
to converter housing ........ 36 + 2 lb. ft. (49 + 3 Nm)
1-38