TM 5 3805-260-24(1) Torque for bolts that hold impellerto turning housing ...............20 1 lb. ft. (27 1 N·m)(2) Clearance between turbine and turning housing:Across the diameter............ .020 to .040 in. (0.51 to 1.02 mm)Maximum permissible clearance:Across the diameter..................................... .045 in. (1.14 mm)Running.................................... .0225 in. (0.57 mm)(3) Torque for bolts that hold retainerto turning housing ...............36 2 lb. ft. (49 3 N·m)(4) Torque for bolts that hold drive gearfor pump to impeller ...................20 1 lb.. ft.. (27 1 Nm)(5) Torque for bolt that holds bearing onoutput shaft .....................81 4 lb.. ft.. (110 5 N·m)(6) Torque for the bolts that hold statorto the converter housing .......362 lb.. ft.. (49 3 N·m)(7) Torque for the bolts that hold statorto the carrier......................20 1 lb.. ft.. (27 1 N·m)(8) Torque for the bolts that hold flangeto the output shaft36 2 lb. ft. (49 3 Nm)(9) Gap in seal rings. .005 to .015 in. (0.13 to 0.38 mm)(10) Clearance between stator and turbine:Across the diameter.. .012 to .018 in. (0.30 to 0.46 mm)Running............... .006 to .009 in. (0.15 to 0.3 mm)Maximum permissible clearance:Across the diameter.................. .030 in. (0.76 mm)Running..................................... .015 in. (0.38 mm)(11) Clearance between stator and impeller:Across the diameter. . .009 to .015 in. (0.23 to 0.38 mm)Running......... .0045 to .0075 in. (0.11 to 0.19 mm)Maximum permissible clearance:Across the diameter.................. .024 in. (0.61 mm)Running..................................... .012 in. (0.30 mm)(12) Torque for bolts that hold retainerto converter housing ........ 36 + 2 lb. ft. (49 + 3 Nm)1-38
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business