TM 5-3805-260-24
TRANSMISSION AND SCAVENGE PUMP
Rotation is counterclockwise when seen from the drive gear. For bench
test use SAE 10W oil at 120° F (49°C).
(1)
Pressure section:
Output...............................24.3 U.S. gpm (91.97 litre/min)
with pump at .......................................................2855 rpm
at a pressure of ........... 310 psi (21 8 kg/cm2) (2137 kPa)
(2)
Scavenge section:
Output.................................9.7 U.S. gpm (36.73 litre/min)
with pump at .......................................................2855 rpm
at a pressure of .................. 60 psi (4.2 kg/cm²) (414 kPa)
(3) Torque for bolts................................36 2 lb. ft. (49 3 N·m)
(4)
Diameter of shafts ............................... .88 in (22.4 mm)
TRANSMISSION HYDRAULIC CONTROLS
(8S3437)
(1)
Torque for the bolts
(12point head) ...........................22 3 lb. ft. (30 4 N·m)
(2)
Torque for the bolts
(6 point head) ............................35 5 lb. ft. (48 7 N·m)
(3)
Torque for the bolts (two) that hold control levers
to the shaft.................................35 5 lb. ft. (48 7 N·m)
NOTE: Put 7M7260 Liquid Gasket on bore surface in transmission case
for the lip-type seals and let dry. Do not let Liquid Gasket get on the case
of the lip-type seals. Put a small amount of the lubricant being sealed on
the lip of the seals before installation
1-41