DAILY NOTES (CONTINUED)
Note 3
TRANSMISSION, STEER UNIT, AND TRANSFER CASE
Access through rear floor plates (TM 5-2350-262-10).
I
I
CAUTION
Do not overfill steer unit. Failure to comply may
result in damage to equipment.
Note
.
The level on the steer unit gage is the level of all
three units.
.
Engine must be running.
Start engine and run at idle speed (750 to 850 rpm) for
A
3 to 5 minutes.
Check oil level on gage (1). Oil should be in COLD
B
IDLE or OPERATING RANGE of gage (1).
C
Add oil, OE/HDO-10 or OEA, through fill point (2), as
necessary.
Remove excess oil if necessary. Use oil sample hose or
D
syringe, if available.
Take oil samples every 30 days. Refer to TB 43-0210
E
for sampling requirements and card 3 for oil sampling
procedures.
Card 6 of 28
LO 5-2350-262-12