TM 5-2350-262-20-3
4
BUMP STOPS INOPERATIVE (CONTINUED)
NO
from block 5
9
Perform bump stop cylinder leakage test.
Does cylinder fully extend in less than
two seconds?
NO
YES
10
Perform bump stop circuit 11 test.
Is hydraulic pressure less than 2,500 psi
(17,238 kPa)?
YES
NO
To block 13
11
Remove all test equipment and
connect hose.
Verify problem with operator
12
Connect BUMP STOP CYL-11 hose.
Replace or repair bump stop cylinder.
3-48