TM 5-2350-262-20-3
2
3
1
EJECTOR CIRCUIT PRESSURE CHECK
WARNING
Do not operate ejector when personnel are in bowl. Do not work in
bowl unless ejector lock is engaged. Failure to comply may result
in severe injury or death to personnel.
Start engine, move ejector halfway forward, stop engine, and relieve hydraulic pressure.
NOTE
Have suitable container ready to catch oil.
Disconnect line (1) from elbow (2) and cap line.
Connect pressure measuring device (3) to elbow (2) on port 21 of ejector control valve.
Have assistant start engine and hold EJECTOR CONTROL lever in the FORWARD
position. Read pressure measuring device (3).
3-79