TM 5-2350-262-20-3
17
WINCH WILL NOT PULL RATED LOAD
The winch hydraulic motor receives oil flow from control valve through circuit VA to PAY OUT cable and through
circuit VB to PAY IN cable. Hydraulic pressure is controlled by winch relief valve C2. The winch motor case drain
line is 7W.
WARNING
High pressure is present in the M9 hydraulic system. Do not disconnect any hydraulic
system component unless hydraulic system pressure has been relieved. Ensure each
hydraulic control lever is moved several times through all positions and hydraulic tank
dipstick is slowly loosened to relieve pressure. Failure to comply may result in severe
injury or death to personnel.
CAUTION
Do not reuse drained captured hydraulic oil unless it has been filtered and is clean.
Failure to comply may result in damage to equipment.
NOTE
DELETED
35,000 LB (15,890 KG) WINCH
Change 2