ELECTRICAL SYSTEM
ELECTRICAL SYSTEM - Continued

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  29    30    31    32    33  34  35    36    37    38    39  
img
.
TM 5-2350-377-13&P
0011
ELECTRICAL SYSTEM - Continued
STEP
3.
Check headlight plug and headlight connector for continuity.
a.
Remove lamp (Figure 2, Item 6) and blackout bulb (Figure 2, Item 4) from body (Figure 2, Item 1).
b.
Disconnect plug J2 (Figure 2, Item 5) from lamp (Figure 2, Item 6) and remove blackout bulb
(Figure 2, Item 4).
c.
Remove connector J1 (Figure 2, Item 2) and body (Figure 2, Item 1) from base (Figure 2, Item 3).
d.
Check for continuity between contacts on plug J2 (Figure 2, Item 5) and connector J1 (Figure 2, Item 2).
e.
Connections for lamp are listed in Table 1 and blackout bulb connections are listed in Table 2.
3
2
1
1
5
4
6
T00302HBF
Figure 2. Headlight Connectors.
Table 1. Headlight Connector Pinout.
J1
J2
Low Beam
C
2
High Beam
D
1
Ground
A
3
Table 2.
Blackout Marker Connector Pinout.
J1
J2
BO Marker
B
Contact
Ground
A
Body
0011-3
03/15/2011Rel(1.8)root(tswp)wpno(T00003)