TROUBLESHOOTING PROCEDURES - TRACK (LEFT OR RIGHT) WILL NOT TIGHTEN OR LOOSEN, HBF-TT SYSTEM (ELECTRICAL)
Figure 2. Control Wire Harness.

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
img
. .
TM 5-2350-377-13&P
0012
ELECTRICAL SYSTEM - Continued
STEP
1.
Check for ground continuity.
a.
Disconnect control box power harness (Figure 1, Item 4) from control box (Figure 1, Item 2).
b.
Check for ground continuity from socket E (Figure 1, Item 1) to ground (Figure 1, Item 3) behind
instrument panel.
1
2
5
4
3
T00401HBF
Figure 1. Control Box Power Harness.
CONDITION/INDICATION
Is continuity present?
DECISION
YES - If continuity is indicated, go to Step (2).
NO - If an open circuit is indicated, replace control box wiring harness (WP 0027). Verify that problem is solved.
STEP
2.
Check control box power wiring harness for a minimum of 24 VDC at socket C.
a.
Using volt meter with negative lead in socket E (Figure 1, Item 1) and positive lead in socket C
(Figure 1, Item 5), turn on master switch.
b.
Turn master switch off.
CONDITION/INDICATION
Are 24 VDC present at socket C?
0012-2