TM 5-3800-205-10-1
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CS Scraper - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
WARNING
83
Monthly
Wheels and
(Con't)
Tires
Use a self-inflating chuck and stand at a distance behind tire
when inflating tire. Failure to do so could result in injury or
death to personnel.
e. Adjust air pressure in tire as
required to 45 psi (310 kPa), using
pneumatic tire inflation hose assem-
00). Connection point to
machine's
air supply is quick disconnect fitting
at rear of hood on right side of trac-
tor.
f. Install valve stem cap.
TIRE INFLATION
HOSE ASSEMBLY
390-1712
AIR CHUCK
QUICK DISCONNECT
84
Monthly
0.5 Hours Tiedown D-
Lubricate all tiedown D-rings on each
Rings
side of tractor and scraper bowl (total
of 12 grease fittings: 4 on tractor; 8 on
scraper) with GAA grease (Item 10,
0014 00-62