TM 5-3800-205-10-1
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CS Scraper - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
78
Weekly
Ether Cold
Start System
WARNING
Ether fuel is extremely flammable and toxic. DO NOT
smoke and make sure you are in a well-ventilated area
away from heat, open flames or sparks. Wear eye protec-
tion. Avoid contact with skin and eyes and avoid breathing
ether fumes. If fluid enters or fumes irritate the eyes, wash
immediately with large quantities of clean water for 15
minutes. Seek medical attention immediately if ether is
inhaled or causes eye irritation. Failure to follow this warn-
ing may cause death or serious injury to personnel.
a. Check for loose connections and a. Damage or evidence of
leaks are noted. Ether can-
damage to lines, fittings, and ether
ister is missing, if required
canister. Ensure canister is securely
for mission.
mounted. Be alert for odor of leak-
ing ether.
b. Check and install protective cap on
fitting when ether canister is not
installed.
PROTECTIVE CAP
(ETHER CANISTER NOT INSTALLED)
ETHER
CANISTER
390-1274
390-1716
0014 00-58