TM 5-3800-205-10-1
RAIL TRANSPORT - CONTINUED
0021 00
RETURN MACHINE TO OPERATIONAL CONFIGURATION - CONTINUED
i.
Remove two bolts and cover with O-ring from speed reducer. Return cover with O-ring and mounting bolts to ISU-
60 container toolbox.
BOLT
SPEED
REDUCER
COVER
WITH
O-RING
BOLT
390-1070
j.
Install elevator motor to speed reducer with two washers and bolts that were moved in step g. Tighten bolts to
158 lb-ft (214 Nm). Remove lifting device from elevator motor.
CAUTION
Always wipe ends clean prior to disconnecting hydraulic lines. Ensure ends are clean prior to reconnect-
ing. Failure to do so may introduce contamination into hydraulic system.
NOTE
All quick disconnect connections are made the same way. Be sure to turn quick disconnect collar a half
turn after connecting to lock connection.
0021 00-39