TM 5-3800-205-23-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0007 00
Table 11. Water Distributor Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13.Water Tank Drifts Up and Down When Tank
1. Check drift of tank hydraulic
If drift exceeds 0.31 in. (7.9
Control Lever is in Hold Position.
cylinders:
mm), go to test step 2.
a. Lift water tank 6-10 in.
(15-25 cm).
b. Move control lever to hold
position.
c. After three (3) minutes,
make a mark on side of
tank at bottom of draft
arm. Mark should also be
6 in. (15 cm) from front of
water tank side.
d. After five (5) minutes,
make a measurement for
drift.
e. Drift on a new machine
should not be more than
0.31 in. (7.9 mm).
2. Check hydraulic cylinder(s)
a. Repair any leaks if required.
for external leakage.
b. If cylinder(s) are damaged,
replace cylinder(s) (TM 5-
3800-205-23-3).
END OF WORK PACKAGE