TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
Change oil in water pump bearing
25
Annual
0.5 Hours Water Pump
housing:
Bearing
Housing
a. Access water pump under steps at
rear of water distributor.
b. Clean area around drain, level, and
filler plugs with a clean rag (Item
c. Remove drain plug and allow oil to
drain into a suitable container. Dis-
pose of oil in accordance with local
policy and ordinances.
FILLER PLUG
LEVEL
PLUG
WATER PUMP BEARING HOUSING
DRAIN PLUG
d. Clean drain plug and install.
e. Remove level and filler plugs.
00) until drainage is
noted from
level plug. Clean level and filler
plugs and install.
0010 00-69