TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
26
Annual
Foot Valve
Remove foot valve access plate and
Assembly
clean debris from foot valve screen.
Reinstall plate (TM 5-3800-205-23-
3).
a. Remove, clean, and reinstall the
27
Annual
Water Dis-
following drain plugs: front tank
tributor
drain, upper spray bar drain, and
Tank
water pump housing drain.
b. Inspect can breaker/bag cutter com-
ponents at tank rear access opening
for corrosion, looseness or other
damage. Replace any damaged
component (TM 5-3800-205-23-3).
c. Inspect front inspection cover and
rear access opening for corrosion or
damage. Replace any damaged
component (TM 5-3800-205-23-3).
Inspect spray heads for corrosion,
28
Annual
Upper Spray
looseness or damage. Replace any
Bar Spray
damaged component (TM 5-3800-
Heads
205-23-3).
Inspect nozzles on lower spray bar and
29
Annual
Lower Spray
de-icing extensions for corrosion,
Bar and De-
looseness or damage. Replace any
icing Exten-
damaged nozzle (TM 5-3800-205-23-
sion Nozzles
3).
0010 00-70